Our organization insists all along the quality policy of "product quality is base of business survival; purchaser gratification is the staring point and ending of an business; persistent improvement is eternal pursuit of staff" as well as the consistent purpose of "reputation 1st, purchaser first" for Smart Ev Charger, Dc 400 V Spd, Spd, Leading the trend of this field is our persistent objective. Supplying first class solutions is our intention. To create a beautiful upcoming, we wish to cooperate with all close friends in the home and overseas. Should you have got any interest in our products and solutions, remember to never wait to call us.
2021 High quality Spd 2p 40ka 800v - HS2-I-50 Lightning Current Arresters – HONI electric Detail:

Features/Benefifits

Easy installation or retrofifit
Din-rail mountable
Fail-safe /self-protected design
IP20 fifinger-safe design
Small foot print

Plug-in format

HS210-I-50 is the most robust range of Type 1/Class I lightning current arresters, able to discharge energy (current) from a direct lightning strike (10/350) on an external lightning protection system (LPS) or overhead supplies, in accordance with EN/IEC 61643-11. DIN rail monobloc format.
■Suitable as a fifirst step of protection in incoming power supply panels and in areas of high atmospheric exposure.
■Discharges impulse currents with a 10/350 μs waveform: 50 kA per phase.
■Exclusive devices for TNS, TNC, TT , IT earthing systems.
■Exclusive devices which are compatible with Power Line Communication networks.
■Biconnect – two types of terminal: for rigid or flflexible cable and for fork type comb busbar.

Data sheet

TypeTechnical DataNominal line voltage (Un) HS210-I-50 230/400 V (50/60Hz)
Maximum continuous voltage (UC) (L-N)

255V

Maximum continuous voltage (UC) (N-PE)

255V

SPD to EN 61643-11

Type 1

SPD to IEC 61643-11

class I

Lightning impulse current (10/350μs) (Iimp)

50kA

Nominal discharge current (8/20μs) (In)

50kA

Voltage protection level (Up) (L-N)

≤ 2.0kV

Voltage protection level (Up) (N-PE)

≤ 2.0kV

Response time (tA) (L-N)

< 100ns

Response time (tA) (N-PE)

< 100ns

Operating State/Fault Indication

no

Degree of protection

IP 20

Insulating material / flammability class

PA66,UL94 V-0

Temperature range

-40ºC~+80ºC

Altitude

13123 ft [4000m]

Conductor Cross Section (max)

35mm2 (Solid) / 25mm2 (Flexible)

Remote Contacts (RC)

no

Format

Monobloc

For mounting on

DIN rail 35mm

Place of installation

indoor installation

Dimensions

HS2-I-50 Power Surge Protector 001

●The power must be cut off before installation, and live operation is strictly prohibited
●It is recommended to connect a fuse or automatic circuit breaker in series at the front of the lightning protection module
●When installing, please connect according to the installation diagram. Among them, L1, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After installation, close the automatic circuit breaker (fuse) switch
●After installation, check whether the lightning protection module is working properly 10350gs, discharge tube type, with window: during use, the fault display window should be checked and checked regularly. When the fault display window is red (or the remote signal terminal of the product with remote signal output alarm signal), it means the lightning protection module In the event of failure, it should be repaired or replaced in time.
●Parallel power supply lightning protection modules should be installed in parallel (Kevin wiring can also be used), or double wiring can be used. Generally, you only need to connect any one of the two wiring posts. The connecting wire must be firm, reliable, short, thick, and straight.


Product detail pictures:

2021 High quality Spd 2p 40ka 800v - HS2-I-50 Lightning Current Arresters – HONI electric detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of 2021 High quality Spd 2p 40ka 800v - HS2-I-50 Lightning Current Arresters – HONI electric , The product will supply to all over the world, such as: Norwegian, Greenland, Jordan, We have been perfectly devoted to the design, R&D, manufacture, sale and service of hair products during 10 years of development. We have introduced and are making full use of internationally advanced technology and equipment, with advantages of skilled workers. "Dedicated to providing reliable customer service" is our aim. We are sincerely looking forward to establishing business relationships with friends from at home and abroad.
  • Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Odelia from Qatar - 2017.10.27 12:12
    As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Penelope from Botswana - 2018.06.03 10:17
    Write your message here and send it to us