Looking for Exclusive Agency and Distributor! Welcome Contact:0086-18966276297 0086-577-61718910

page_head_bg

8 Year Exporter Surge Protector Device Spd Price - HS2-I-50 Lightning Current Arresters – HONI electric


Product Detail

Product Tags

Related Video

Feedback (2)

Our rewards are reduce selling prices,dynamic revenue team,specialized QC,sturdy factories,superior quality services for Mains Voltage-Dependent Rcbos, Surge Protector Device Spd Price, Dc Rccb, Our tenet is "Reasonable prices, economical production time and very best service" We hope to cooperate with much more shoppers for mutual enhancement and benefits.
8 Year Exporter Surge Protector Device Spd Price - HS2-I-50 Lightning Current Arresters – HONI electric Detail:

Features/Benefifits

Easy installation or retrofifit
Din-rail mountable
Fail-safe /self-protected design
IP20 fifinger-safe design
Small foot print

Plug-in format

HS210-I-50 is the most robust range of Type 1/Class I lightning current arresters, able to discharge energy (current) from a direct lightning strike (10/350) on an external lightning protection system (LPS) or overhead supplies, in accordance with EN/IEC 61643-11. DIN rail monobloc format.
■Suitable as a fifirst step of protection in incoming power supply panels and in areas of high atmospheric exposure.
■Discharges impulse currents with a 10/350 μs waveform: 50 kA per phase.
■Exclusive devices for TNS, TNC, TT , IT earthing systems.
■Exclusive devices which are compatible with Power Line Communication networks.
■Biconnect – two types of terminal: for rigid or flflexible cable and for fork type comb busbar.

Data sheet

TypeTechnical DataNominal line voltage (Un) HS210-I-50 230/400 V (50/60Hz)
Maximum continuous voltage (UC) (L-N)

255V

Maximum continuous voltage (UC) (N-PE)

255V

SPD to EN 61643-11

Type 1

SPD to IEC 61643-11

class I

Lightning impulse current (10/350μs) (Iimp)

50kA

Nominal discharge current (8/20μs) (In)

50kA

Voltage protection level (Up) (L-N)

≤ 2.0kV

Voltage protection level (Up) (N-PE)

≤ 2.0kV

Response time (tA) (L-N)

< 100ns

Response time (tA) (N-PE)

< 100ns

Operating State/Fault Indication

no

Degree of protection

IP 20

Insulating material / flammability class

PA66,UL94 V-0

Temperature range

-40ºC~+80ºC

Altitude

13123 ft [4000m]

Conductor Cross Section (max)

35mm2 (Solid) / 25mm2 (Flexible)

Remote Contacts (RC)

no

Format

Monobloc

For mounting on

DIN rail 35mm

Place of installation

indoor installation

Dimensions

HS2-I-50 Power Surge Protector 001

●The power must be cut off before installation, and live operation is strictly prohibited
●It is recommended to connect a fuse or automatic circuit breaker in series at the front of the lightning protection module
●When installing, please connect according to the installation diagram. Among them, L1, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After installation, close the automatic circuit breaker (fuse) switch
●After installation, check whether the lightning protection module is working properly 10350gs, discharge tube type, with window: during use, the fault display window should be checked and checked regularly. When the fault display window is red (or the remote signal terminal of the product with remote signal output alarm signal), it means the lightning protection module In the event of failure, it should be repaired or replaced in time.
●Parallel power supply lightning protection modules should be installed in parallel (Kevin wiring can also be used), or double wiring can be used. Generally, you only need to connect any one of the two wiring posts. The connecting wire must be firm, reliable, short, thick, and straight.


Product detail pictures:

8 Year Exporter Surge Protector Device Spd Price - HS2-I-50 Lightning Current Arresters – HONI electric detail pictures


Related Product Guide:

We now have a skilled, performance team to supply good quality services for our consumer. We often follow the tenet of customer-oriented, details-focused for 8 Year Exporter Surge Protector Device Spd Price - HS2-I-50 Lightning Current Arresters – HONI electric , The product will supply to all over the world, such as: Kuwait, Accra, United Kingdom, In the new century, we promote our enterprise spirit "United, diligent, high efficiency, innovation", and stick to our policy"basing on quality, be enterprising, striking for first class brand". We would take this golden opportunity to create bright future.
  • The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By James Brown from Lesotho - 2017.05.02 11:33
    In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Alan from Qatar - 2017.10.13 10:47
    Write your message here and send it to us