Products

Our MCB breaking capacity is up to 10-15KA , the DC

voltage for MCB MCCB SPD is up to 1500V.

HS2-I-25 Lightning Current Arresters

Application

AC/DC distribution
Power supplies
Industrial automation
Telecommunications
Motor controls systems
PLC applications
Power transfer equipment
HVAC applications
AC drives
UPS systems
Security systems
IT / Data centers
Medical equipment
Features/Benefifits

Easy installation or retrofifit

Din-rail mountable

Fail-safe /self-protected design

Remote indicator (optional) with 3 pin NO/NC contact

IP20 fifinger-safe design

Visual indicator

Small foot print

Plug-in format

HS25-C40-PV series of DC Surge Protective Device (SPD) for use in Photovoltaic applications. surge protective devices provide protection from lightning current and overvoltage surges in system from 500Vdc to 1500Vdc.

Providing power with photovoltaic solar panels is tremendously interesting in the context of renewable energy sources, as regards economical photovoltaic systems connected to the public electricity network. Because of their exposition, frequently in isolated sites and of the extended surface of photovoltaic systems (PV), lightning strikes are a major components in the risk to be assumed, both for the direct effect of lightning on the structures, and of the surge overvoltages on the installation.

Cells are generally associated with inverters. CUAJE® has developed a specifc Din

Rail product to protect DC side of cells and inverters against surge in power plant or residential application.

With the MOV (Metal Oxside Varistor), the overvoltage will be limited at the value of the voltage protection level of the OBV5-C40-PV DC surge protector. Our surge protector, as recommended in standards and guides, insure all protections (between + and-, + and Ground, – and Ground). On each surge arrester, as option, an available auxiliary contact will inform the end life status to ensure a maximum effciency.

Dimensions
Data sheet
TypeTechnical Data Network configuration

HS25-C40-PV

Photovoltaic (PV)

Maximum continuous voltage (UC)

600 / 900 / 1000 / 1200 / 1500Vdc

SPD to EN 61643-11

Type 2

SPD to IEC 61643-11

class II

Nominal discharge current (8/20μs) (In)

20kA

Maximum discharge current (8/20μs) (Imax)

40kA

Voltage protection level (Up)

≤ 2.5 / 3.0 / 3.2 / 3.6 / 4.5kV

Response time (tA)

< 25ns

Thermal Protection

YES

Operating State/Fault Indication

Green (good) / Red (replace)

Degree of protection

IP 20

Insulating material / flammability class

PA66,UL94 V-0

Protective Elements

High Energy MOV

Temperature range

-40ºC~+80ºC

Altitude

13123 ft [4000m]

Conductor Cross Section (max)

35mm2 (Solid) / 25mm2 (Flexible)

Remote Contacts (RC)

Optional

Format

Pluggable

Internal configuration

(Y) or (U)

For mounting on

DIN rail 35mm

Place of installation

indoor installation

×
Please use this form to order our products
good service
Blank Form (#3)