Products

Our MCB breaking capacity is up to 10-15KA , the DC

voltage for MCB MCCB SPD is up to 1500V.

HO212/214 10kA Residual current circuit breaker withovercurrent protection

This standard applies to our company produced HO212/214-63 residual current circuitbreaker with over current protection.The circuit breaker has good current limitingperformance, and can accurately protect the line from overload, short circuit, leakagecurrent and other fault hazards.HO212/214-63 series circuit breakers (hereinafter referred to as circuit breakers) aresuitable for AC 50/60Hz, rated voltage not exceeding 415V, rated current to 63A, toprotect line facilities and electrical equipment in buildings and similar places, and alsofor infrequent on-off operations.

Short-circuit protection function
Overload protection function
Leakage protection function
Controlfunction
Isolation function
Normal working conditions and installation conditions
Ambient temperature range-5 C ~+40C,Average temperature not exceeding +35 C in24H
AltitudeThe elevation of the installation site does not exceed 2000m
Atmospheric conditions+40*C,50%+20C,90%
Class of pollutionlevel2
Installation conditionTH35-7.5 steel mounting rail according to JB6525-1992
Installation siteInstall it vertically, with the handle facing upward to poweron
Other requirements for installationThere should be no significant shock and vibration at theinstallation site.
Storage conditions and requirements
Storage methodVentilation; Relative humidity does not exceed 80%6,; Noacid, alkaline and corrosive gases in the air
Storage temperature-25C-+70C
Storage timeFrom the date of production, the products shall not bestored for more than 3 years under the above conditions
Parameters
Product modelHO212 H0214
StandardIEC61009-1
Trip curveB,C,D
Rated current (In)6,10,16,20,25,32,40,63 4
Rated voltage(Ue)240V/415V
Insulation Voltage(Ui)500V
Rated residual operating current (l△n)30mA,100mA,300mA
Action characteristics of residual currentType-AC,type-A, type-S
Breaking capacity (lcn)10kA
Rated operating short circuit breakingcapacity(lcs)7.5kA
Rated impulse resistance voltage4kY
Rated (residual) on/off capacity (1△m)2000A
Disconnect indicator functionThe green indicator represents the contact open
Surge current resistance/at(8/20)us3KA
Number of product polesTwo poles( 2P), Four poles (4P)
Electric life4000
Mechanical life10000
Trip curveCurve B:Instant trip between 3In and 5lnCurve C:Instant trip between 5In and 10ln
Protection DegreeIP20
×
Please use this form to order our products
good service
Blank Form (#3)