Products

Our MCB breaking capacity is up to 10-15KA , the DC

voltage for MCB MCCB SPD is up to 1500V.

SOLAR PV DC SPD 3P 400V 600V 800V 100V 1100V 1200V 1500V 20-40KA T2 surge protective devices (spd)

Place of Origin: Zhejiang, China
Brand Name: HONI
Model Number: HS2D-50
Product name: Surge Protective Device
Type: T1+T2
Quality: A class
Certificate: CE CB
Usage: PV Solar Systerm
Standard: IEC 61643-1/GB 18802.1
In: 30KA
Imax: 50ka
Protection class: IP40
Product Details

SOLAR PV DC SPD 3P 400V 600V 800V 100V 1100V 1200V 1500V 20-40KA T2 surge protective devices (spd)

HS2D-50 PV series of DC Surge Protective Device (SPD) for use in Photovoltaic applications. surge protective devices provide protection from lightning current and overvoltage surges in system from 500Vdc to 1500Vdc.

Providing power with photovoltaic solar panels is tremendously interesting in the context of renewable energy sources, as regards economical photovoltaic systems connected to the public electricity network. Because of their exposition, frequently in isolated sites and of the extended surface of photovoltaic systems (PV), lightning strikes are a major components in the risk to be assumed, both for the direct effect of lightning on the structures, and of the surge overvoltages on the installation.

Cells are generally associated with inverters. we has developed a specifc Din Rail product to protect DC side of cells and inverters against surge in power plant or residential application.

With the MOV (Metal Oxside Varistor), the overvoltage will be limited at the value of the voltage protection level of the HS2D-50-DC-PV DC surge protector. Our surge protector, as recommended in standards and guides, insure all protections (between + and-, + and Ground, – and Ground). On each surge arrester, as option, an available auxiliary contact will inform the end life status to ensure a maximum effciency.

Data sheet
Technical /ModelHS2D-50
Maximum continuous voltage (UC)500/600 / 900 / 1000 / 1200 / 1500Vdc
SPD to EN61643-11Type 1+2/Class I+Ⅱ
Nominal discharge current (8/20μs) (In)30kA
Maximum discharge current (8/20μs) (Imax)50kA
Voltage protection level (Up)≤ 2.5 / 3.0 / 3.2 / 3.6 / 4.5kV
Response time (tA)< 25ns
Thermal ProtectionYES
Operating State/Fault IndicationGreen (good) / Red (replace)
Degree of protectionIP 20
Insulating material/fireproof grade  PA66,UL94 V-0
Protective ElementsHigh Energy MOV
Temperature range  PA66,UL94 V-0
Insulating material/fireproof grade -40ºC~+80ºC
Altitude  4000m
Conductor Cross Section (max)35mm2 (Solid) / 25mm2 (Flexible)
Remote Contacts (RC)Optional
FormatPluggable
Internal configuration(Y) or (U)
For mounting on DIN rail 35mm
Place of installationIndoor installation
×
Please use this form to order our products
good service