Products

Our MCB breaking capacity is up to 10-15KA , the DC

voltage for MCB MCCB SPD is up to 1500V.

PV DC Combiner Box 4 Inputs / 2 Outputs | 1000V DC | 32A | IP65

Outdoor wall-mount steel enclosure with integrated DC breaker, fuse and surge protection.

System voltage:1000V DC
Protection rating:32A
Enclosure:IP65
Overall size:500×300×200 mm
Product Overview

The HONI 4-in / 2-out PV DC combiner box is a compact DC-side protection assembly for photovoltaic systems. It combines two protected DC branches in one IP65 wall-mount enclosure. The supplied drawing shows 1000V DC, 32A protection, 10×38 DC fuse protection and Type 2 40kA DC surge protection, with a dedicated PE grounding bar.

Key Design Features
  • 4-input / 2-output PV DC configuration (project requirement).
  • Two independent protected DC circuits in one enclosure.
  • 2 × 32A / 4P DC1000V circuit breakers shown in the engineering drawing.
  • 4 × ATPV-DC1000V 32A, 10×38 fuse positions shown in the engineering drawing.
  • 2 sets of Type 2, 40kA, DC1000V surge protection.
  • Dedicated protective-earth terminal bar and lid earth bonding.
  • IP65 outdoor wall-mount enclosure, RAL7035, 1.2mm cold-rolled steel.
  • 11 prepared PG11 cable-entry holes at the bottom.
Mechanical & Serviceability
  • Symmetrical internal layout supports straightforward inspection and replacement.
  • DIN-rail mounted protection devices.
  • Clear DC input/output and polarity labels.
  • Dedicated earth bar improves grounding organization.
Engineering Drawing & Protection Architecture

The supplied engineering drawing defines the enclosure construction and the duplicated DC protection circuits.

Typical Application

PV array / string DC-side protection and distribution before downstream inverter or DC equipment. Final string voltage, current, polarity, conductor size and protective-device selection must be checked against the project electrical design.

Technical Specifications

Parameter

Specification

Product type

PV DC Combiner Box

Configuration

4 Inputs / 2 Outputs

Drawing reference

HL1

Rated system voltage

DC 1000V

Protection current

32A (breaker/fuse rating shown in drawing)

DC circuit breaker

2 pcs × 4P, 32A, DC1000V

DC fuse protection

4 pcs × ATPV-DC1000V, 32A, 10×38

DC surge protection

2 sets × Type 2, 40kA, DC1000V

Protective earth

Central PE grounding bar; lid bonding conductor

Enclosure protection

IP65

Enclosure size

W500 × H300 × D200 mm (including door/lid, per drawing)

Enclosure material

1.2 mm cold-rolled steel

Surface finish / color

Powder-coated RAL7035

Installation

Outdoor wall mounting

Door / lid locking

Latch locks

Cable entry

11 × PG11 installation holes at bottom

×
Please use this form to order our products