PV AC Grid-Tied Box 400V 63A IP65 with SPD, Isolation & Metering Provision

The HONI PV AC Grid-Tied Box is a compact outdoor cabinet for the AC side of photovoltaic grid-connected systems. It integrates 4-pole protection, isolation, AC surge protection, earthing and reserved metering / CT positions in a two-compartment IP65 steel enclosure. The configuration can be adapted to the approved project BOM for different solar installations.

400 V / 63 A AC System
IP65 Outdoor Steel Enclosure
4-Pole Protection & Isolation
AC SPD: In 40 kA / Imax 80 kA
Metering / CT Provision
Project-Based OEM Configuration
Feature

Feature

explanation

Integrated AC protection

A coordinated enclosure for protective circuit breakers, isolation, AC SPD, earthing and metering interfaces.

IP65 outdoor construction

1.2 mm cold-rolled steel enclosure with RAL 7035 outdoor powder coating and independent lockable doors.

Two-compartment layout

Separates the metering / terminal area from the main protective switching area for easier inspection and field service.

4-pole architecture

Typical configuration uses four-pole switching suitable for three-phase + neutral AC grid connection.

Surge protection branch

Typical 4P AC SPD requirement: In 40 kA and Imax 80 kA, subject to final approved project design.

Metering-ready design

Reserved positions for metering / current-transformer arrangements allow project-specific monitoring or utility interface integration.

Project engineering

Final breaker ratings, SPD selection, metering, CT arrangement, cable access and labels are confirmed against the project BOM before production.

Technical specifications

Parameter

Specification

Rated voltage

AC 400 V

Rated current

63 A (nameplate configuration shown)

Electrical arrangement

4-pole AC

Ingress protection

IP65

Enclosure material

1.2 mm cold-rolled steel

Color

RAL 7035

Surface treatment

Outdoor powder coating, internal and external surfaces; 60–120 µm

Dimensions

550 × 850 × 220 mm, including door (nominal drawing dimension)

Operating temperature

-25 °C to +60 °C

Storage temperature

-40 °C to +80 °C

Relative humidity

0–100% RH, non-condensing

Installation

Outdoor wall-mounted / surface installation

Cable entry

Bottom cable entry / exit openings according to project drawing

Typical internal configuration

Component

Typical specification

Qty

Automatic reclosing circuit breaker

NBP-100NGVE, 4P, C50A, PV application

1 pc

Protection circuit breaker

DZ47-63, 4P, C63

1 pc

Knife switch / isolator

HK1N-63/4F

1 pc

AC surge protective device

4P SPD; In 40 kA / Imax 80 kA requirement

1 set

Earthing bar

Standard grounding bar

1 pc

Metering / CT provision

Reserved area; typical documentation shows positions for 2 meters and 7 terminal/junction boxes

Project-specific

Application

Typical applications include the AC output side of commercial rooftop PV systems, small solar plants, inverter-to-grid connection points, project-specific AC protection cabinets, and installations requiring an integrated metering / CT interface. Final electrical ratings and protection coordination must be selected for the actual inverter output, grid conditions and project requirements.

Customization block

Engineering customization available
Circuit-breaker rating • SPD specification • metering / CT arrangement • cable-entry layout • enclosure labeling • project BOM • neutral / customer branding. Final configuration is confirmed before production.

Recommended CTA

Main CTA
SEND US YOUR SINGLE-LINE DIAGRAM OR PROJECT REQUIREMENTS
Our engineers will confirm the breaker rating, SPD, metering / CT arrangement, enclosure layout and BOM before quotation.

FAQ
What is a PV AC grid-tied box?

It is an AC-side protection and grid-connection cabinet installed between the photovoltaic inverter output and the utility / project AC distribution point. The configuration can integrate switching, surge protection, isolation, earthing and metering interfaces.

The configuration shown is a 4-pole AC arrangement with a nameplate rated voltage of AC 400 V and rated current of 63 A. Final selection must match the inverter output and project design.

The enclosure is specified as IP65 and is designed for outdoor wall-mounted installation.

The typical drawing specifies a 4-pole AC SPD branch with In 40 kA and Imax 80 kA. The final SPD type and parameters should be confirmed for the project.

The typical BOM includes a 4-pole C50A automatic reclosing circuit breaker. The protection and reclosing logic can be finalized according to the approved project configuration.

Yes. The design includes a reserved metering / CT area. The supplied project documentation shows positions for two meters and seven terminal / junction boxes.

Yes, the final breaker, SPD, metering and CT selections are confirmed against the approved project BOM before production.

The nominal drawing dimension is 550 × 850 × 220 mm including the door.

The enclosure is specified as 1.2 mm cold-rolled steel with RAL 7035 outdoor powder coating.

Please send the inverter AC output voltage, maximum current or inverter power, grid system, required quantity, SPD requirement, metering / CT requirement and, if available, the single-line diagram.

×