Our MCB breaking capacity is up to 10-15KA , the DC
voltage for MCB MCCB SPD is up to 1500V.
The HONI PV AC Grid-Tied Box is a compact outdoor cabinet for the AC side of photovoltaic grid-connected systems. It integrates 4-pole protection, isolation, AC surge protection, earthing and reserved metering / CT positions in a two-compartment IP65 steel enclosure. The configuration can be adapted to the approved project BOM for different solar installations.
Feature | explanation |
Integrated AC protection | A coordinated enclosure for protective circuit breakers, isolation, AC SPD, earthing and metering interfaces. |
IP65 outdoor construction | 1.2 mm cold-rolled steel enclosure with RAL 7035 outdoor powder coating and independent lockable doors. |
Two-compartment layout | Separates the metering / terminal area from the main protective switching area for easier inspection and field service. |
4-pole architecture | Typical configuration uses four-pole switching suitable for three-phase + neutral AC grid connection. |
Surge protection branch | Typical 4P AC SPD requirement: In 40 kA and Imax 80 kA, subject to final approved project design. |
Metering-ready design | Reserved positions for metering / current-transformer arrangements allow project-specific monitoring or utility interface integration. |
Project engineering | Final breaker ratings, SPD selection, metering, CT arrangement, cable access and labels are confirmed against the project BOM before production. |
Parameter | Specification |
Rated voltage | AC 400 V |
Rated current | 63 A (nameplate configuration shown) |
Electrical arrangement | 4-pole AC |
Ingress protection | IP65 |
Enclosure material | 1.2 mm cold-rolled steel |
Color | RAL 7035 |
Surface treatment | Outdoor powder coating, internal and external surfaces; 60–120 µm |
Dimensions | 550 × 850 × 220 mm, including door (nominal drawing dimension) |
Operating temperature | -25 °C to +60 °C |
Storage temperature | -40 °C to +80 °C |
Relative humidity | 0–100% RH, non-condensing |
Installation | Outdoor wall-mounted / surface installation |
Cable entry | Bottom cable entry / exit openings according to project drawing |
Component | Typical specification | Qty |
Automatic reclosing circuit breaker | NBP-100NGVE, 4P, C50A, PV application | 1 pc |
Protection circuit breaker | DZ47-63, 4P, C63 | 1 pc |
Knife switch / isolator | HK1N-63/4F | 1 pc |
AC surge protective device | 4P SPD; In 40 kA / Imax 80 kA requirement | 1 set |
Earthing bar | Standard grounding bar | 1 pc |
Metering / CT provision | Reserved area; typical documentation shows positions for 2 meters and 7 terminal/junction boxes | Project-specific |
Typical applications include the AC output side of commercial rooftop PV systems, small solar plants, inverter-to-grid connection points, project-specific AC protection cabinets, and installations requiring an integrated metering / CT interface. Final electrical ratings and protection coordination must be selected for the actual inverter output, grid conditions and project requirements.
Engineering customization available
Circuit-breaker rating • SPD specification • metering / CT arrangement • cable-entry layout • enclosure labeling • project BOM • neutral / customer branding. Final configuration is confirmed before production.
Main CTA
SEND US YOUR SINGLE-LINE DIAGRAM OR PROJECT REQUIREMENTS
Our engineers will confirm the breaker rating, SPD, metering / CT arrangement, enclosure layout and BOM before quotation.
It is an AC-side protection and grid-connection cabinet installed between the photovoltaic inverter output and the utility / project AC distribution point. The configuration can integrate switching, surge protection, isolation, earthing and metering interfaces.
The configuration shown is a 4-pole AC arrangement with a nameplate rated voltage of AC 400 V and rated current of 63 A. Final selection must match the inverter output and project design.
The enclosure is specified as IP65 and is designed for outdoor wall-mounted installation.
The typical drawing specifies a 4-pole AC SPD branch with In 40 kA and Imax 80 kA. The final SPD type and parameters should be confirmed for the project.
The typical BOM includes a 4-pole C50A automatic reclosing circuit breaker. The protection and reclosing logic can be finalized according to the approved project configuration.
Yes. The design includes a reserved metering / CT area. The supplied project documentation shows positions for two meters and seven terminal / junction boxes.
Yes, the final breaker, SPD, metering and CT selections are confirmed against the approved project BOM before production.
The nominal drawing dimension is 550 × 850 × 220 mm including the door.
The enclosure is specified as 1.2 mm cold-rolled steel with RAL 7035 outdoor powder coating.
Please send the inverter AC output voltage, maximum current or inverter power, grid system, required quantity, SPD requirement, metering / CT requirement and, if available, the single-line diagram.