Products

Our MCB breaking capacity is up to 10-15KA , the DC

voltage for MCB MCCB SPD is up to 1500V.

HO232-60 HO234-40 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

Breaking Capacity: 10000A
Rated Voltage: 400V, 400V
Rated Current: 125A
BCD Curve: C
Type: RCBO, Earth Leakage
Rated Frequency (Hz): 50/60Hz
Number of Pole: 4
Protection: Li poles: 3P+N,4P
Characteristic: B,C.D
Rated current (A): 1 2 3 4 6 10 16 20 25 32 40 50 63 80 100 125
Rated short-circuit capacity: 10KA
Mechanical Life: 20000
Rated short circuit capacity Icn: 7.5kA
leakage current: 30ma,100ma,300MA,500MA
Rated Frequency: 50/60hz
Place of Origin: Zhejiang, China
Brand Name: HONI
Model Number: HO234
Product Details

It is electro-mechanical in nature. The highlight here is that:

1. it can be wired in either direction.

2.It is accord with IEC 61009-2-1 (mains voltage independent RCBO), It is with electro-mechanical release that works safely even without supply voltage or line voltage lower than 50V.

3.Type -A: Protects against special forms of residual pulsating DC which have not been smoothed.

4.Provides protection against earth fault/leakage current, short-circuit,overload, and function of isolation.

5.Provides complementary protection against direct contact by human body Effectively protects electric equipment against insulating failure.

6.Provides comprehensive protection to household and commercial distribution systems.

7.high breaking capacity up to 10ka.more secure.

Specification

By combination with miniature circuit breaker => RCBO-Unit (MCCB) Add-on residual current unit (screw connection) for 80 or 125 A (2-pole and 4-pole)

• High flfl exibility and ease of installation thanks to variable wiring (400 mm flfl exible connection wires 2p = 2 units, 4p = 4 units included in the set)
• Free selection of main power supply
• Auxiliary switch 1 NO included as standard in all FBHmV versions
• Permits combinations with a variety of characteristics thanks to the different rated currents and characteristics of the miniature circuit breakers AZ which can be connected
• For trade and industry applications
• For subsequent mounting onto 2, 3, 3+N and 4-pole-miniature circuit breakers
• Toggle (serves as switch position- and tripping indicator)
• The screw connection to the device can be unscrewed at any time. Consequently, in case of modififi cations of the systems to be protected, the installation can be adapted to new requirements at any time.
• The test key “T” must be pressed every 6 months. The system operator must be informed of this obligation and his responsibility in a way that can beproven. Under special conditions (e.g. damp ly and/or dusty environments,environments with polluting and/or corroding conditions, environments with large temperature flfl uctuations, installations with a risk of overvoltages due to switching of equipment and/or atmospheric discharges, portable equipment…), it’s recommended to test in monthly intervals.
• Pressing the test key “T” serves the only purpose of function testing the residual current device (RCD). This test does not make earthing resistance measurement (RE), or proper checking of the earth conductor condition redun dant, which must be performed separately

10ka breaking capacity test reports
Dimensions (mm)
Technical Data
ITEMSDATA
TypeElectro-magnetic type
Residual current characteristicsAC, A
Pole No.1P+N,3P+N
Rated short-circuit capacity10000A
Rated current (A)1P+N:6,10,16,20,25,32,40,50,60A; 3P+N:
 6,10,16,20,25,32,40A
Rated voltage240V/415V AC
Rated frequency50/60Hz
Rated residual operating current(mA)10,30,100,300
Tripping durationinstantaneous 0.1s
Tripping characteristicsB,C,D
Rated short-circuit breaking capacity10000A
Rated impulse withstand voltageUimp 4kV(1.2/50μs)
Endurance 
Electrical components≥ 4,000 operating cycles
Mechanical components≥ 1,0000 operating cycles
Connection terminalpillar terminal with clamp
Frame size45 mm
Device height80 mm
Device width35 mm (2MU)
Mounting3-position DIN rail clip, permits removal from existing
 busbar system
Degree of protection switchIP20
Degree of protection, built-inIP40
Upper and lower terminalsopen mouthed/lift terminals
Terminal protectionfinger and hand touch safe, DGUV VS3, EN 50274
Terminal capacity1-25 mm2
Terminal torque2-2.4 Nm
Busbar thickness0.8-2 mm
Operation temperature-25℃ to +40℃
Storage- and transport temperature-35℃ to +60℃
Resistance to climatic conditionsacc. to IEC 68-2 (25..55℃ / 90..95% RH)
×
Please use this form to order our products
good service
Blank Form (#3)