Our progress depends within the advanced products, fantastic talents and repeatedly strengthened technology forces for Best quality Power Surge Protector 2p 3p AC SPD Class B+C Power SPD Protector Surge Protective Device, You would not have any communication problem with us. We sincerely welcome prospects all around the planet to call us for business enterprise cooperation.
Our progress depends within the advanced products, fantastic talents and repeatedly strengthened technology forces for China Arrester and Surge Protective Devices, Our goods have won an excellent reputation at each of the related nations. Because the establishment of our firm. we’ve insisted on our production procedure innovation together with the most recent modern day managing method, attracting a sizable quantity of talents within this industry. We regard the solution good quality as our most vital essence character.
Features/Benefifits
Plug-in format
Data sheet
TypeTechnical DataNominal line voltage (Un) | HS210-I-50 230/400 V (50/60Hz) |
Maximum continuous voltage (UC) (L-N) |
255V |
Maximum continuous voltage (UC) (N-PE) |
255V |
SPD to EN 61643-11 |
Type 1 |
SPD to IEC 61643-11 |
class I |
Lightning impulse current (10/350μs) (Iimp) |
50kA |
Nominal discharge current (8/20μs) (In) |
50kA |
Voltage protection level (Up) (L-N) |
≤ 2.0kV |
Voltage protection level (Up) (N-PE) |
≤ 2.0kV |
Response time (tA) (L-N) |
< 100ns |
Response time (tA) (N-PE) |
< 100ns |
Operating State/Fault Indication |
no |
Degree of protection |
IP 20 |
Insulating material / flammability class |
PA66,UL94 V-0 |
Temperature range |
-40ºC~+80ºC |
Altitude |
13123 ft [4000m] |
Conductor Cross Section (max) |
35mm2 (Solid) / 25mm2 (Flexible) |
Remote Contacts (RC) |
no |
Format |
Monobloc |
For mounting on |
DIN rail 35mm |
Place of installation |
indoor installation |
Dimensions
●The power must be cut off before installation, and live operation is strictly prohibited
●It is recommended to connect a fuse or automatic circuit breaker in series at the front of the lightning protection module
●When installing, please connect according to the installation diagram. Among them, L1, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After installation, close the automatic circuit breaker (fuse) switch
●After installation, check whether the lightning protection module is working properly 10350gs, discharge tube type, with window: during use, the fault display window should be checked and checked regularly. When the fault display window is red (or the remote signal terminal of the product with remote signal output alarm signal), it means the lightning protection module In the event of failure, it should be repaired or replaced in time.
●Parallel power supply lightning protection modules should be installed in parallel (Kevin wiring can also be used), or double wiring can be used. Generally, you only need to connect any one of the two wiring posts. The connecting wire must be firm, reliable, short, thick, and straight.Our progress depends within the advanced products, fantastic talents and repeatedly strengthened technology forces for Best quality Power Surge Protector 2p 3p AC SPD Class B+C Power SPD Protector Surge Protective Device, You would not have any communication problem with us. We sincerely welcome prospects all around the planet to call us for business enterprise cooperation.
Best quality China Arrester and Surge Protective Devices, Our goods have won an excellent reputation at each of the related nations. Because the establishment of our firm. we’ve insisted on our production procedure innovation together with the most recent modern day managing method, attracting a sizable quantity of talents within this industry. We regard the solution good quality as our most vital essence character.