  • HO212/214 10kA Residual current circuit breaker withovercurrent protection

    HO212/214 10kA Residual current circuit breaker withovercurrent protection

    This standard applies to our company produced HO212/214-63 residual current circuitbreaker with over current protection.The circuit breaker has good current limitingperformance, and can accurately protect the line from overload, short circuit, leakagecurrent and other fault hazards.HO212/214-63 series circuit breakers (hereinafter referred to as circuit breakers) aresuitable for AC 50/60Hz, rated voltage not exceeding 415V, rated current to 63A, toprotect line facilities and electrical equipment in buildings and similar places, and alsofor infrequent on-off operations.

  • HO232-60/HO234-40 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

    HO232-60/HO234-40 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

    Breaking Capacity: 10000A
    Rated Voltage: 400V, 400V
    Rated Current: 125A
    BCD Curve: C
    Type: RCBO, Earth Leakage
    Rated Frequency (Hz): 50/60Hz
    Number of Pole: 4
    Protection: Li
    poles: 3P+N,4P
    Characteristic: B,C.D
    Rated current (A): 1 2 3 4 6 10 16 20 25 32 40 50 63 80 100 125
    Rated short-circuit capacity: 10KA
    Mechanical Life: 20000
    Rated short circuit capacity Icn: 7.5kA
    leakage current: 30ma,100ma,300MA,500MA
    Rated Frequency: 50/60hz
    Place of Origin: Zhejiang, China
    Brand Name: HONI
    Model Number: HO234

  • HO252-80/HO254-80 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

    HO252-80/HO254-80 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

    It is Electronic type in nature. The highlight here is that:
    1.Type -A: Protects against special forms of residual pulsating DC which have not been smoothed.
    2.Provides protection against earth fault/leakage current, short-circuit, overload, and function of isolation.
    3.Provides complementary protection against direct contact by human body Effectively protects electric equipment against insulating failure.
    4.Provides comprehensive protection to household and commercial distribution systems.
    5.L Pole and N pole Both have the overload protection. 6.High breaking capacity up to 10KA ,more secure.

  • HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

    HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

    By combination with miniature circuit breaker => RCBO-Unit (MCCB) Add-on residual current unit (screw connection) for 80 or 125 A (2-pole and 4-pole)

    • High flfl exibility and ease of installation thanks to variable wiring (400 mm flfl exible connection wires 2p = 2 units, 4p = 4 units included in the set)

    • Free selection of main power supply

    • Auxiliary switch 1 NO included as standard in all FBHmV versions

    • Permits combinations with a variety of characteristics thanks to the differentrated currents and characteristics of the miniature circuit breakers AZ which can be connected

  • HO202-C32 HO204-C32 Rears Residual Current Circuit Breaker with Overcurrent Protection

    HO202-C32 HO204-C32 Rears Residual Current Circuit Breaker with Overcurrent Protection

    • Provides protection against earth fault/leakage current, short-circuit, overload, and function of isolation

    • Provides complementary protection against direct contact by human body

    • Effectively protects electric equipment against insulating failure

    • Provides comprehensive protection to household and commercial distribution systems

    • 4 Gears rated residual operating current(mA):30,20,10,6

  • RCCB-B-80A Residual Current Circuit Breaker

    RCCB-B-80A Residual Current Circuit Breaker

    It is electro-mechanical in nature.The highlinght here is that it can be wired in either direction.This makes retrofit a breeze with regards to matching wiring conventions.it also busbar campatible

  • Top Quality 1P 2P 3P 4P AC 230V 6A 16A 20A 40A 63A L7 DPN MCB Circuit Breaker

    Top Quality 1P 2P 3P 4P AC 230V 6A 16A 20A 40A 63A L7 DPN MCB Circuit Breaker

    Construction and Feature

    ■Protection against both overload and short circuit

    ■High short-circuit capacity

    ■Easy mounting onto 35mm DIN rail

  • 1P 2P 3P 4P AC240V 415V Modular Ac Contactor Circuit Breaker

    1P 2P 3P 4P AC240V 415V Modular Ac Contactor Circuit Breaker

    AC Contactor is mainly designed for AC 50HZ or 60HZ circuits with 230V rated operating voltage. In AC-7a usage rated operating voltage up to 230V, rated operating current up to 100A, it functions as long distance breaking and circuit controlling. This product is mainly applied to household appliances or low inductance loading and home electromotor loading control used for the similar purpose

  • HM231D-C63/ HM232D-C63/ HM233D-63/ HM234D-C63 DC Miniature Circuit Breaker

    HM231D-C63/ HM232D-C63/ HM233D-63/ HM234D-C63 DC Miniature Circuit Breaker

    This DC MCB Was designed for direct current(DC) control circuit applications,used for short -circuit and over-current protection within appliances or electrical equipment.
    It provide optimization products for DC system applications such as.

    1. In large capacity, high voltage power system or power plants,DC system offer steady power supply for relay protection, operation control, signal and emergency lighting audio equipment .Mini dc circuit breaker will guarantee the safty of the power system.

    2. PV,EPS,UPS Power system

    3. Special Rapid analysis DC circuit breaker is important for rail transit and electrocar.

    4. In Marine power system,Dc circuit breaker is one of the most important components to ensure the safety of power supply system and electrical equipment of ships.

  • HO231N-40 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

    HO231N-40 Residual Current Circuit Breaker With Over-Current Protection (RCBO)

    The new RCBO is a single pole plus switched neutral device where the line/load can be connected from top or bottom. Having no restriction to the connection of supply enhances the safety of your installation and the compact.Single pole size allows more poles to fit into assemblies offering a cost effective solution.

    • Fully conforms to AS/NZS 61009-1

    • Compliant to Energy Safe Victoria – Additional Testing Requirements for RCBOs.

    • Rated current up to 40A

    • Type AC and Type A sensitivity devices available

    It achieved Australia SAA certificate ,and pass the ESV test ,It is can be wired in either direction

  • Residual Current Circuit Breaker With Overload Protection

    Residual Current Circuit Breaker With Overload Protection

    HO231N series Residual Current Circuit Breaker with Overcurrent Protection (hereinafter referred to as the circuit breaker) is suitable for use in ac 50 Hz,nominal voltage 230/400V,use in household and similar place with rated current to 40 A or below.Mainly provide protection to the personal electrical shock and  ground fault of line equipment, also can be used to protect lines or equipment overload and short circuit.At the same time the product with isolation function, can be used in normal circumstances as the not frequent changeover of line.

    Carried Standard: GB16917.1 IEC61009

  • HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)

    HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)

    It is electro-mechanical in nature. The highlight here is that:

    1.It can be wired in either direction.

    2.It is accord with IEC/EN 61008-1 (mains voltage independent RCCB), It is with electro-mechanical release that works safely even without supply voltage or line voltage lower than 50V.

    3.Type -A: Protects against special forms of residual pulsating DC which have not been smoothed.

    4.Protection of persons against electric shock by direct contact (30 mA).

    5.Protection of persons against electric shock by indirect contact (300 mA).

    6.Protection of installations against fire risks (300 mA).

    7. Provides comprehensive protection to household and commercial distribution systems.