Factory wholesale 2p 4p Electronic Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric Detail:

Overview

By combination with miniature circuit breaker => RCBO-Unit (MCCB) Add-on residual current unit (screw connection) for 80 or 125 A (2-pole and 4-pole)

• High flfl exibility and ease of installation thanks to variable wiring (400 mm flfl exible connection wires 2p = 2 units, 4p = 4 units included in the set)

• Free selection of main power supply

• Auxiliary switch 1 NO included as standard in all FBHmV versions

• Permits combinations with a variety of characteristics thanks to the different rated currents and characteristics of the miniature circuit breakers AZ which can be connected

• For trade and industry applications

• For subsequent mounting onto 2, 3, 3+N and 4-pole-miniature circuit breakers

• Toggle (serves as switch position- and tripping indicator)

• The screw connection to the device can be unscrewed at any time. Consequently, in case of modififi cations of the systems to be protected, the installation can be adapted to new requirements at any time.

• The test key “T” must be pressed every 6 months. The system operator must be informed of this obligation and his responsibility in a way that can be proven. Under special conditions (e.g. damp ly and/or dusty environments, environments with polluting and/or corroding conditions, environments with large temperature flfl uctuations, installations with a risk of overvoltages due to switching of equipment and/or atmospheric discharges, portable equipment …), it’s recommended to test in monthly intervals.

• Pressing the test key “T” serves the only purpose of function testing the residual current device (RCD). This test does not make earthing resistance measurement (RE), or proper checking of the earth conductor condition redundant, which must be performed separately

Technical Data

Electrical
Design according toCurrent test marks as printed onto the device IEC/EN 61009
Tripping Instantaneous 250A (8/20μs), surgecurrent-proof
Rated voltage                      Un 240/415V AC
Voltage range test circuit
2-poles
4-poles, 30mA
4-poles, 100, 300, 500,
196-264 V~
196-264 V~
196-456 V~
Rated frequency 50 Hz
Rated tripping current               I△n 30, 300, 500, 1000 mA
Rated non-tripping current           I△no 0.5 I△n
Sensitivity AC and pulsating DC
Rated current                       In 80, 125 A
Rated short circuit breaking capacity   Ics 10kA
Rated short circuit capacity           Icn 7.5kA
Rated impulse withstand voltage      Uimp 4 kV (1.2/50μs)
Endurance
electrical components
80A
125A
mechanical components
80A
125A³

≥1,500 operating cycles
≥ 1,000 operating cycles

≥ 10,000 operating cycles
≥ 8,000 operating cycles

Electrical Auxiliary Contact
Rated voltage               Ue 250 V AC
Rated operational current     Ie 16 A AC
Mechanical
Frame size 45 mm
Device height 90 mm
Device width 95 mm (5,5TE)
Depth of central body 60 mm
Mounting screwed onto AZ 2-, 3-, 4-poles;
Degree of protection switch IP20
Degree of protection, built-in IP40
Upper and lower terminals lift terminals
Terminal protection fifinger and hand touch safe
Terminal capacity
main conductor
auxiliary switch
2.5 – 50 mm²
1 – 25 mm²
Operation temperature -25°C to +40°C
Storage- and transport temperatureResistance to climatic conditions -35°C to +60°Cacc. to IEC 68-2 (25..55°C / -90..95% RH)

Dimensions(mm)

table
HO232-(1)

HM232-125

HO232-(3)

HM232-125

HO232-(2)

HM232-125

HO234-(1)

HM234-125


Product detail pictures:

Factory wholesale 2p 4p Electronic Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric detail pictures

Factory wholesale 2p 4p Electronic Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric detail pictures

Factory wholesale 2p 4p Electronic Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric detail pictures

Factory wholesale 2p 4p Electronic Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric detail pictures


Related Product Guide:

continue to improve, to ensure product quality in line with market and customer standard requirements. Our company has a quality assurance system have been established for Factory wholesale 2p 4p Electronic Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric , The product will supply to all over the world, such as: Indonesia, Angola, Swiss, Only for accomplishing the good-quality product to meet customer's demand, all of our products have been strictly inspected before shipment. We always think about the question on the side of the customers, because you win, we win!
  • The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Marian from Egypt - 2018.06.30 17:29
    We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Elva from Germany - 2018.06.19 10:42
    Write your message here and send it to us