Looking for Exclusive Agency and Distributor! Welcome Contact:0086-18966276297 0086-577-61718910

page_head_bg

Featured

  • Excellent quality Pv Rccb - HO232-60/HO234-40 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric

    Excellent quality Pv Rccb - HO232-60/HO234-40 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric

    10ka breaking capacity test reports Technical Data ITEMS DATA Type Electro-magnetic type Residual current characteristics AC, A Pole No. 1P+N,3P+N Rated short-circuit capacity 10000A Rated current (A) 1P+N:6,10,16,20,25,32,40,50,60A; 3P+N: 6,10,16,20,25,32,40A Rated voltage 240V/415V AC Rated frequency 50/60Hz Rated residual operating current(mA) 10,30,100,300 Tripping duration instantaneous 0.1s Tripping characteristics B,C,D Rated short-circuit breaking cap...
  • PriceList for Electronic A Type 10ka Rcbo - HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB) – HONI electric

    PriceList for Electronic A Type 10ka Rcbo - HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB) – HONI electric

    Technical Data Electrical characteristics Insulation voltage (Ui) 400 V Pollution degree 3 Rated impulse withstand voltage (Uimp) 4 kV Electrical Characteristics   According to IEC/EN 61008-1 Surge currentwithstand (8/20 μs)withouttripping AC and A types (notselective     ) 1250A AC, A,(selective    ) 3 k Conditional ratedshort-circuit current(Inc/IDc) With FU 125 A gG fuse 10,000 A Behaviour in case ofvoltage drop   Residual current protection down to 0 V accord...
  • Wholesale Price China 10ka Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric

    Wholesale Price China 10ka Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric

    Overview By combination with miniature circuit breaker => RCBO-Unit (MCCB) Add-on residual current unit (screw connection) for 80 or 125 A (2-pole and 4-pole) • High flfl exibility and ease of installation thanks to variable wiring (400 mm flfl exible connection wires 2p = 2 units, 4p = 4 units included in the set) • Free selection of main power supply • Auxiliary switch 1 NO included as standard in all FBHmV versions • Permits combinations with a variety of characteristics thanks to the d...
  • 2021 China New Design Dc Ev Charger - HQ3 and HQ5 EV Charger – HONI electric

    2021 China New Design Dc Ev Charger - HQ3 and HQ5 EV Charger – HONI electric

    HQ3 and HQ5 EV Charger Our EV Charger is a single-phase and three-phase EV Charging Box, solely used for ac charging of electric vehicles. The equipment adopts industrial design principles. The protection level of the EV Charging Box reaches IP55, with good dust-proof and water-proof functions, and can be operated and maintained safely outdoors. This series Electric Vehicle Charging Box come in two version: the cable version and the socket version,smooth and concise appearance, the char...
  • New Arrival China 4p Electromagnetic Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric

    New Arrival China 4p Electromagnetic Rcbo - HM232-125/HM234-125 Residual Current Circuit Breaker With Over-Current Protection (RCBO) – HONI electric

    Overview By combination with miniature circuit breaker => RCBO-Unit (MCCB) Add-on residual current unit (screw connection) for 80 or 125 A (2-pole and 4-pole) • High flfl exibility and ease of installation thanks to variable wiring (400 mm flfl exible connection wires 2p = 2 units, 4p = 4 units included in the set) • Free selection of main power supply • Auxiliary switch 1 NO included as standard in all FBHmV versions • Permits combinations with a variety of characteristics thanks to the d...
  • Manufacturer of Dc Spd 1000v Surge Protection Device - HS2T-BNC Data and Signal Surge Protection – HONI electric

    Manufacturer of Dc Spd 1000v Surge Protection Device - HS2T-BNC Data and Signal Surge Protection – HONI electric

    Features/Benefifits Easy installation Fail-safe /self-protected design Very fast response Hybrid GDT and Diode Technology Long distance transmission Good transmission effect Strong anti-interference complies IEC 61643-21 standard SPD for CCTV Camera HS2T-BNC is the series of devices for discharging transient overvoltages induced in coaxial lines. In accordance with IEC 61643-21. Coaxial format. ■Suitable for the protection of coaxial lines of TV and CCTV systems. By their nature, they are hig...
  • High reputation 100v Spd - wholesale 3 phase 10-20ka 385V SPD,overvoltage Power surge protection,lightning protection class II+III spd HS2-10 – HONI electric

    High reputation 100v Spd - wholesale 3 phase 10-20ka 385V SPD,overvoltage Power surge protection,lightning protection class II+III spd HS2-10 – HONI electric

    Features/Benefifits Easy installation or retrofit Din-rail mountable Fail-safe /self-protected design Remote indicator (optional) with 3 pin NO/NC contact IP20 finger-safe design Visual indicator Small foot print Data sheet Type HS25-D10 Technical Data Maximum continuous voltage (UC) (L-N) 275 / 320 / 385 / 420V Maximum continuous voltage (UC) (N-PE) 275V SPD to EN 61643-11 Type 3 SPD to IEC 61643-11 class III Nominal discharge current (8/20μs) (In) 5kA ...
  • Factory source Ac Spd 1p 40ka - HS2-I-15 Power Surge Protector – HONI electric

    Factory source Ac Spd 1p 40ka - HS2-I-15 Power Surge Protector – HONI electric

    Features/Benefifits Easy installation or retrofifit Din-rail mountable Fail-safe /self-protected design Remote indicator (optional) with 3 pin NO/NC contact IP20 fifinger-safe design Visual indicator Small foot print Plug-in format HS210-I-15 is the most robust range of Type 1/Class I lightning current arresters, able to discharge energy (current) from a direct lightning strike (10/350) on an external lightning protection system (LPS) or overhead supplies, in accordance with EN/IEC 61643-11. ...
  • OEM/ODM China Electromagnetic Rcbo - HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB) – HONI electric

    OEM/ODM China Electromagnetic Rcbo - HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB) – HONI electric

    Technical Data Electrical characteristics Insulation voltage (Ui) 400 V Pollution degree 3 Rated impulse withstand voltage (Uimp) 4 kV Electrical Characteristics   According to IEC/EN 61008-1 Surge currentwithstand (8/20 μs)withouttripping AC and A types (notselective     ) 1250A AC, A,(selective    ) 3 k Conditional ratedshort-circuit current(Inc/IDc) With FU 125 A gG fuse 10,000 A Behaviour in case ofvoltage drop   Residual current protection down to 0 V accord...
  • Factory source Ev Charger Price - HQ3 and HQ5 EV Charger – HONI electric

    Factory source Ev Charger Price - HQ3 and HQ5 EV Charger – HONI electric

    HQ3 and HQ5 EV Charger Our EV Charger is a single-phase and three-phase EV Charging Box, solely used for ac charging of electric vehicles. The equipment adopts industrial design principles. The protection level of the EV Charging Box reaches IP55, with good dust-proof and water-proof functions, and can be operated and maintained safely outdoors. This series Electric Vehicle Charging Box come in two version: the cable version and the socket version,smooth and concise appearance, the char...
  • Reasonable price Type B Rccb - RCCB-B-80A Residual Current Circuit Breaker – HONI electric

    Reasonable price Type B Rccb - RCCB-B-80A Residual Current Circuit Breaker – HONI electric

    Scope of application In addition to fault currents in the AC and pulse current range,type B also detects DC fault currents,which can occur in frequency inverter controls,photovoltaic systems as well as through the electronic use in households,and increases safety considerably Applications with In addition to fault currents in the AC and pulse current range,type B also detects DC fault currents,which can occur in frequency inverter controls,photovoltaic systems as well as through the electroni...
  • High reputation 100v Spd - HS2-I-15 Power Surge Protector – HONI electric

    High reputation 100v Spd - HS2-I-15 Power Surge Protector – HONI electric

    Features/Benefifits Easy installation or retrofifit Din-rail mountable Fail-safe /self-protected design Remote indicator (optional) with 3 pin NO/NC contact IP20 fifinger-safe design Visual indicator Small foot print Plug-in format HS210-I-15 is the most robust range of Type 1/Class I lightning current arresters, able to discharge energy (current) from a direct lightning strike (10/350) on an external lightning protection system (LPS) or overhead supplies, in accordance with EN/IEC 61643-11. ...