We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our management ideal for Type 2 Ac Charger For Ev, Dc 400 V Spd, 16a Ev Charger, Welcomes all overseas friends and merchants to establish collaboration with us. We will provide you with honest, high quality and efficient service to meet your requirements.
High definition Dc Rccb - RCCB-B-80A Residual Current Circuit Breaker – HONI electric Detail:

Scope of application

In addition to fault currents in the AC and pulse current range,type B also detects DC fault currents,which can occur in frequency inverter controls,photovoltaic systems as well as through the electronic use in households,and increases safety considerably

Applications with

In addition to fault currents in the AC and pulse current range,type B also detects DC fault currents,which can occur in frequency inverter controls,photovoltaic systems as well as through the electronic use in households,and increases safety considerably

● Applications with:

. Appliances and motors with 1Phase frequency converters with PFC([Power factor compensation)or .1 phase frequency converters supplied between phase/phase or .3 phase frequency converters

. DC systems(photovoltaic systems,ups units..)

. In front of PV Systems/ Battery banks/ UPS Units/EV charging Medical devices/ Frequency converters/ Motor controllers

. Sensitive to all residual currents according up to lkHz.

Residual Current Devices-General Data
Short description of the most important RCD types:
Symbol Description
RCCB-B-80A-2    HONI standard. Suitable for outdoor installation (distribution boxes for outdoor installation and building sites+-25 up to -25℃ .
RCCB-B-80A-3    Type AC: AC current sensitive RCCB
RCCB-B-80A-4    Type A: AC and pulsating DC current sensitive RCCB
RCCB-B-80A-5    Trip also at frequency composition(10 Hz,50 Hz, 1000 Hz)
RCCB-B-80A-6    Type B:All-current sensitive RCD switchgear for applications where DC fault currents may occur.Non-selective non- delayed. Protection against all kinds of fault currents.

Electrical characteristics

ITEMS DATA
Rated voltage 1P+N 240V,3P+N 415V
Rated current 16A 25A 32A 40A 80A
Rated residual operating current 0.03A,0.1A,0.3A,0.5A
Rated residual current type AC+A+DC+F+high frequency 1kHz
Rated impulse withstand voltage(Uimp) 4kv
According to IEC/EN 61008-1
Making and breaking capacity(Im/IDm) 1250A
Surge current withstand(8/20 ㎲)without tripping B types(selective) 3 kA
B types(no selective) 3 kA
Rated short-circuit Bresking Capability 1000A
Addition characteristics
Degree of protection Device only IP20IP40 with screw shield
Device in modular enclosure IP40Insulation class ll
Endurance(O-C) Electrical >2000 cycles
Mechanical >5000 cycles
Operatingtemperature    RCCB-B-80A-8 -25℃to+60℃/-40℃F to +140°F
Storage temperature B type -40℃to+60℃/-40℃F to +140°F
Range of test button operating voltage 30mA 2P 160…250V AC
4P 250…440V AC
100,300,500mA 2P 185…250VAC
4P 185…440V AC
Connectinf capactity 16 mm2
Tightening torque 3N.m
Pollution degree Level 2
Installation Category ll

Weight(g/oz)

Rwsidual current circuit breakers
Type RCCB-B-80A
2P 230g/8.11oz
4P 500g/17.64oz

Dimensions (mm / inches) RCCB-B-80A

RCCB-B-80A-2


Product detail pictures:

High definition Dc Rccb - RCCB-B-80A Residual Current Circuit Breaker – HONI electric detail pictures

High definition Dc Rccb - RCCB-B-80A Residual Current Circuit Breaker – HONI electric detail pictures

High definition Dc Rccb - RCCB-B-80A Residual Current Circuit Breaker – HONI electric detail pictures

High definition Dc Rccb - RCCB-B-80A Residual Current Circuit Breaker – HONI electric detail pictures


Related Product Guide:

Adhering to the principle of "quality, service, efficiency and growth", we have gained trusts and praises from domestic and international client for High definition Dc Rccb - RCCB-B-80A Residual Current Circuit Breaker – HONI electric , The product will supply to all over the world, such as: Bangladesh, Australia, Jakarta, In order to meet more market demands and long-term development, a 150, 000-square-meter new factory is under construction, which will be put into use in 2014. Then, we shall own a large capacity of producing. Of course, we are going to continue improving the service system to meet the requirements of customers, bringing health, happiness and beauty to everyone.
  • The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
    5 Stars By Dora from Monaco - 2017.09.16 13:44
    The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Michelle from Jeddah - 2018.11.28 16:25
    Write your message here and send it to us