With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the best value for our customers for Elcb 10ma, Dc Fast Ev Charger Type2, Cassette 10 Spd, Welcomes all overseas friends and merchants to establish collaboration with us. We will provide you with honest, high quality and efficient service to meet your requirements.
Hot New Products 10ka Mcb - Residual Current Circuit Breaker With Overload Protection – HONI electric Detail:

HO232-40 Electronic Rcbo

1
4
2
3

HO232 Residual Current Circuit Breaker with Overcurrent Protection (RCBO)

Construction and Feature

■Provides protection against earth fault/leakage current, short-circuit, overload, and function of isolation

■Provides complementary protection against direct contact by human body

■Effectively protects electric equipment against insulating failure

■Provides comprehensive protection to household and commercial distribution systems

Technical Data

■Type:Electro type, Electro-magnetic type

■Residual current characteristics: AC,A   Selling point:The A type product after the design, three angles (0 degrees, 90 degrees, 135 degrees) the surplus working current scope is very small, positive and negative 4mA, in 16mA-24mA; But other company’s A type product working current scope is very big, between 10mA-36mA.

■Pole No.: 1P+N ,3P+N(Selling point:At present this kind of 4 modulus’s 4P in the RCBO market did not have, in the market present 4P RCBO is assembling)

■Tripping curve: B, C

■Rated short-circuit capacity: 10kA(Selling point: in the 10KA breaking present market did not have)

■Rated current (A): 1P+N:6, 10, 16, 20, 25, 32, 40,50,60A;  3P+N: 6, 10, 16, 20, 25, 32A;

■Rated voltage: 240V AC

■Rated frequency: 50/60Hz

■Rated residual operating current(mA): 30,100,300

■Tripping duration: instantaneous 0.1s

■Electro-mechanical endurance: 4000 cycles

■Connection terminal: pillar terminal with clamp

■Connection capacity:

□Flexible conductor 10mm2

□Rigid conductor 16mm2

■Installation:

□On symmetrical DIN rail 35mm

□Panel mounting

HO232-40 Electromagnetic Rcbo

2
3

HM202-C32

30
31
32
33

HM204-C32

34
35
37
36

Current Adjustable RCBO HM202-C32 + HM204-C32

Construction and Feature

1.Provides protection against earth fault/leakage current, short-circuit, overload, and function of isolation

2.Provides complementary protection against direct contact by human body

3.Effectively protects electric equipment against insulating failure

4.Provides comprehensive protection to household and commercial distribution systems

Technical Data

1.Type:Electro type, Electro-magnetic type

2.Residual current characteristics: AC,A Selling point:The A type product after the design, three angles (0 degrees, 90 degrees, 135 degrees) the surplus working current scope is very small, positive and negative 4mA, in 16mA-24mA; But other company’s A type product working current scope is very big, between 10mA-36mA.

3.Pole No.: 1P+N ,3P+N(Selling point:At present this kind of 4 modulus’s 4P in the RCBO market did not have, in the market present 4P RCBO is assembling)

4.Tripping curve: B, C

5.Rated short-circuit capacity: 10kA(Selling point: in the 10KA breaking present market did not have)

6.Rated current (A) 2P: 6, 10, 16, 20, 25, 32, 40,50,60;

4P:6,10,16,20,25,32;

7.Rated voltage: 230/400V AC

8.Rated frequency: 50/60Hz

9.Rated residual operating current(mA): 6ma ,10ma ,20ma,30ma

10.Tripping duration: instantaneous 0.1s

11.Electro-mechanical endurance: 4000 cycles

HO234-40

1
2
3
4

HO234-40

Construction and Feature

Provides protection against earth fault/leakage current, short-circuit, overload, and function of isolation Provides complementary protection against direct contact by human body

Effectively protects electric equipment against insulating failure

Provides comprehensive protection to household and commercial distribution systems Features

Type:Electro type, Electro-magnetic type

Residual current characteristics: AC,A   Selling point:The A type product after the design, three angles (0 degrees, 90 degrees, 135 degrees) the surplus working current scope is very small, positive and negative 4mA, in 16mA-24mA; But other company’s A type product working current scope is very big, between 10mA-36mA.

Pole No.: 1P+N ,3P+N(Selling point:At present this kind of 4 modulus’s 4P in the RCBO market did not have, in the market present 4P RCBO is assembling)

Technical Data

Pole No.

1P+N ,3P+N

Tripping curve

B, C

Rated current (A)

6, 10, 16, 20, 25, 32, 40

Rated voltage

240V AC

Rated frequency

 50/60Hz

Rated residual operating current(mA)

30,100,300

Tripping duration

instantaneous 0.1s

Electro-mechanical endurance

4000 cycles

Connection terminal

pillar terminal with clamp

Connection capacity

Flexible conductor 10mm2 Rigid conductor 16mm2

Installation

On symmetrical DIN rail 35mm Panel mounting

HO234-63

1
3
2
4

L7 magnetic  residual current circuit breaker 6A 30MA 2P RCBO

Specification

L7 miniature circuit breaker MCB is mainly used for protection against overload and short circuit under the AC 50Hz/60Hz, reted voltage 230V/400V and rated current from 1A to 63A. It also can be used for non-frequent on-and-off switch operation under normal circumstance.

In complicance with IEC/EN60898-1

With indicator function in the contact position.

Bilateral busbar wiring capabilities to adapt to the wider use of premises.Maximum connecting ability of 25mm2, wiring torque 3N*m, applicable to a variety of installing equipments, wiring stronger

Protection calss: IP20

Technical Data

Rated Current In 1A 2A 3A 4A 6A 10A 16A 20A 25A 32A 40A 50A 63A
Poles 1P 2P 3P 4P 1P+N 3P+N
Rated Voltage Ue 1P: 230/400V  2P/3P/4P: 400V
Rated Breaking Capacity 6000A/10000A
Thermo-magnetic release characteristic B C D
Electrical Life 4000
Mechanical Life 10000
Combination with Accessories Auxiliary, Alarm, Shunt Release, Under Voltage Release
Certificate CE CB SEMKO SAA CCC TUV
Guarantee 2YEARS

Product detail pictures:

Hot New Products 10ka Mcb - Residual Current Circuit Breaker With Overload Protection – HONI electric detail pictures

Hot New Products 10ka Mcb - Residual Current Circuit Breaker With Overload Protection – HONI electric detail pictures

Hot New Products 10ka Mcb - Residual Current Circuit Breaker With Overload Protection – HONI electric detail pictures

Hot New Products 10ka Mcb - Residual Current Circuit Breaker With Overload Protection – HONI electric detail pictures

Hot New Products 10ka Mcb - Residual Current Circuit Breaker With Overload Protection – HONI electric detail pictures


Related Product Guide:

We are experienced manufacturer. Wining the majority of the crucial certifications of its market for Hot New Products 10ka Mcb - Residual Current Circuit Breaker With Overload Protection – HONI electric , The product will supply to all over the world, such as: Bangladesh, Rwanda, Bogota, Due to good quality and reasonable prices, our items have been exported to more than 10 countries and regions. We are looking forward to cooperating with all customers from at home and abroad. Moreover, customer satisfaction is our eternal pursuit.
  • The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Victor Yanushkevich from Ireland - 2017.04.08 14:55
    This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Judy from Norway - 2017.08.16 13:39
    Write your message here and send it to us