wholesale 3 phase 10-20ka 385V SPD,overvoltage Power surge protection,lightning protection class II+III spd HS2-10

Application

AC/DC distribution

Power supplies

Industrial automation

Telecommunications

Motor controls systems

PLC applications

Power transfer equipment

HVAC applications

AC drives

UPS systems

Security systems

IT / Data centers

Medical equipment


Product Detail

Product Tags

Features/Benefifits

Easy installation or retrofit
Din-rail mountable
Fail-safe /self-protected design
Remote indicator (optional) with 3 pin NO/NC contact
IP20 finger-safe design
Visual indicator
Small foot print

Data sheet

Type

HS25-D10

Technical Data

Maximum continuous voltage (UC) (L-N)

275 / 320 / 385 / 420V

Maximum continuous voltage (UC) (N-PE)

275V

SPD to EN 61643-11

Type 3

SPD to IEC 61643-11

class III

Nominal discharge current (8/20μs) (In)

5kA

Maximum discharge current (8/20μs) (Imax)

10kA

Voltage protection level (Up) (L-N)

≤ 1.0 / 1.1/ 1.3 / 1.5kV

Voltage protection level (Up) (N-PE)

≤ 1.5kV

Response time (tA) (L-N)

< 25ns

Response time (tA) (N-PE)

< 100ns

Thermal Protection

YES

Operating State/Fault Indication

Green (good) / White or Red (replace)

Degree of protection

IP 20

Insulating material / flammability class

PA66,UL94 V-0

Temperature range

-40ºC~+80ºC

Altitude

13123 ft [4000m]

Conductor Cross Section (max)

35mm2 (Solid) / 25mm2 (Flexible)

Remote Contacts (RC)

Optional

Format

Pluggable

For mounting on

DIN rail 35mm

Place of installation

indoor installation

Plug-in format

HS25-D10 is the range of devices for discharging induced transient overvoltages(Type 3 / Class III), in accordance with EN/IEC 61643-11. DIN rail plug-in format.
Ability to discharge induced voltage surges (8/20 μs). For very fine protection of sensitive equipment(1.2/50 μs). Installation downstream of type 2 protection.
■Suitable as the final stage of protection in panels with Type 2 protection devices installed upstream. The residual voltage left downstream is less than for Type 1 or 2.
They should be installed as close as possible to the equipment being protected.
■Discharge capacity with an 8/20 μs waveform. Imax: 10 kA.
■Exclusive devices for TNS, TNC, TT , IT earthing systems.
■Exclusive devices which are compatible with Power Line Communication networks.
■Biconnect – two types of terminal: for rigid or flexible cable and for fork type comb busbar.
■Available with optional remote signalling.

Dimensions
HS2-10 Power Surge Protector