Products

Our MCB breaking capacity is up to 10-15KA , the DC

voltage for MCB MCCB SPD is up to 1500V.

HONI 4 In 2 Out PV DC Combiner Box 1000VDC 32A IP65 with Type 2 40kA SPD

Integrated 4-input / 2-output PV DC protection box for 1000VDC photovoltaic systems. The enclosure combines two 32A protected DC circuits with 4P DC breakers, 10×38 DC fuses, Type 2 40kA surge protection and a dedicated PE grounding bar in an IP65 RAL7035 steel enclosure.

Voltage:DC1000V.
Current:32A protection rating.
Breaker:2 × 4P, 32A, DC1000V.
Fuse:4 × 32A, DC1000V, 10×38.
SPD:2 sets × Type 2, 40kA, DC1000V.
Enclosure:IP65; 500×300×200 mm; 1.2mm cold-rolled steel; RAL7035.
Cable entry:11 × PG11 installation holes.
Product Overview

The HONI 4 In / 2 Out PV DC Combiner Box is designed for DC-side protection and distribution in photovoltaic installations. It integrates two protected DC branches inside one IP65 wall-mount enclosure, helping simplify field installation and keep DC protection devices organized.

Key Features
  • 4-input / 2-output PV DC configuration.
  • Rated system voltage up to 1000V DC as shown in the supplied project drawing.
  • Two 32A / 4P DC circuit breakers.
  • Four 32A, 10×38 DC fuse positions.
  • Two Type 2, 40kA DC surge-protection sets.
  • Central protective-earth bar with lid earth bonding.
  • IP65, RAL7035, 1.2mm cold-rolled steel enclosure.
  • 500 × 300 × 200 mm wall-mount cabinet.
  • 11 prepared PG11 cable-entry holes at the bottom.
FAQ
What is the configuration of this PV combiner box?

This project is configured as 4 inputs and 2 outputs, with two protected DC branches.

The supplied engineering drawing specifies DC1000V.

The drawing shows two 32A/4P DC breakers, four 32A 10×38 DC fuse positions and two Type 2 40kA DC surge-protection sets.

The enclosure is specified as IP65, suitable for outdoor wall mounting when correctly installed and sealed.

500 × 300 × 200 mm, including the lid/door, according to the supplied drawing.

Configuration changes should be handled as an engineered option. Any changed ratings, component models or cable entries must be reflected in the drawing, datasheet and website page before shipment.

Applications

Suitable for PV DC distribution and protection between solar-array/string circuits and downstream inverter or DC equipment. Project engineers should verify maximum Voc, operating current, conductor sizing, polarity and local installation requirements before use.

Technical Data

Parameter

Specification

Configuration

4 Inputs / 2 Outputs

Rated voltage

DC1000V

Protection current

32A

DC breaker

2 × 4P, 32A, DC1000V

DC fuse

4 × 32A, DC1000V, 10×38

DC SPD

2 sets × Type 2, 40kA, DC1000V

Enclosure

IP65, RAL7035, 1.2mm cold-rolled steel

Dimensions

500 × 300 × 200 mm

Cable entry

11 × PG11 installation holes

×
Please use this form to order our products